# Simulation: forces, actuators, accuracy, air, cycle time

Full swing-arm machine, wire 0.5 to 2.5 mm². All inputs are assumptions written in `sim/sizing.py`; the bench rig measures the uncertain ones.
Air pressure 5 bar, safety factor 2.0 on process forces.

## 1. Process forces and what holds them

| Size mm² | Strip force N (typical) | Design pull-off N | Needed per gripper finger N | Smallest SMC MHZ2 that holds | Cut force N (copper shear) | Crimp force N (design) |
|---|---|---|---|---|---|---|
| 0.5 | 5–12 | 24 | 40 | 20D | 200 | 2250 |
| 0.75 | 6–15 | 30 | 50 | 25D | 300 | 2700 |
| 1.0 | 8–18 | 36 | 60 | 25D | 400 | 3300 |
| 1.5 | 10–25 | 50 | 83 | 32D | 600 | 4200 |
| 2.5 | 15–40 | 80 | 133 | 32D | 1000 | 6000 |

Reading this: the arm grippers must hold the wire while the slug is pulled off. With smooth jaws a large gripper (MHZ2-32D) is needed for 2.5 mm²; serrated jaws (μ 0.5) halve that. Sleeve and strand-guide grippers carry almost no load, so MHZ2-16D is enough there.

## 2. Actuators

| Motion | Load | Result | Choice |
|---|---|---|---|
| Blade close (cut + strip) | 1000 N | 1.06 N·m on a 2 mm lead screw (η 0.3) | NEMA 23 stepper, 1.2 N·m or more |
| Crimp, 2.5 mm² | 6000 N | too big for a direct cylinder; bore 80 mm with a 4:1 toggle | 80 mm cylinder with 4:1 toggle, or a bought pneumatic crimp head |
| Ferrule insertion | 40 N | bore 16 mm | 16 mm air slide (stroke 30) |
| Pull-off slides | 80 N | bore 20 mm | 20 mm air slide (stroke 15), hard stops |
| Wire feed | 40 N drag | 0.40 N·m at roller r 10 mm, 382 rpm, 0.020 mm per microstep | NEMA 23 closed-loop stepper + encoder wheel check |
| Arm A swing (38°, 0.4 s) | J 289 kg·cm² | 0.72 N·m at the arm, 0.080 N·m at the motor (10:1), 317 rpm | NEMA 23 stepper + 10:1 gearbox |
| Arm B swing (30°, 0.4 s) | J 473 kg·cm² | 0.93 N·m at the arm, 0.103 N·m at the motor (10:1), 250 rpm | NEMA 23 stepper + 10:1 gearbox |

## 3. Position accuracy at the stations

The strand guide catches the wire if the tip arrives within about ±1 mm (guide entry is 1.5 mm bigger than the insulation, all round). Gearbox backlash at the arm becomes tip error:

| Arm | Tip radius | Error with 3 arcmin gearbox | Error with 15 arcmin gearbox |
|---|---|---|---|
| A | 198 mm | 0.17 mm | 0.86 mm |
| B | 248 mm | 0.22 mm | 1.08 mm |

A normal planetary gearbox (15 arcmin) puts the tip about 1 mm off: right at the limit. Use either a low-backlash gearbox (3 arcmin or better), or a tapered locating pin at each station that the arm drops onto (cheaper and repeatable). Recommendation: locating pins.

## 4. Cycle time

Each step includes 0.05 s for the controller to confirm the move. Sleeve cutting and ferrule indexing happen while the arms are elsewhere, so they are off the critical path.

| Step | Time s |
|---|---|
| Open head wide, release arm A gripper | 0.20 |
| Feed 112 mm | 0.43 |
| Grip both sides | 0.20 |
| Cut (blade stepper) | 0.20 |
| Score both ends | 0.17 |
| Pull off 12 mm (both slides) | 0.25 |
| Open head wide | 0.20 |
| Swing to sleeve stations (A, B together) | 0.50 |
| Sleeve: nest down, slide on, release, up | 1.63 |
| Swing to ferrule stations | 0.50 |
| Ferrule: guide close, insert, guide open, insert, crimp, release | 1.30 |
| Swing back | 0.70 |
| Discharge (gripper B open) | 0.20 |
| **Total, one finished wire (both ends)** | **6.5** |

About 6.5 s per wire, so roughly 560 wires an hour. The concept animation's 30 s was illustrative. The sleeve step is the longest; two faster slides or a shorter nest travel would cut it.

## 5. Air use

| Actuator | Count | Size | Free air per cycle, L |
|---|---|---|---|
| Arm pull-off slide | 2 | 16 x 15 | 0.072 |
| Sleeve nest down | 2 | 12 x 50 | 0.134 |
| Sleeve slide along wire | 2 | 12 x 70 | 0.188 |
| Ferrule insert slide | 2 | 16 x 30 | 0.143 |
| Ferrule crimp (toggle) | 2 | 80 x 20 | 2.387 |
| Ferrule indexer | 2 | 10 x 10 | 0.019 |
| Arm wire grippers | 2 | 12.0 cm3 | 0.285 |
| Sleeve nest grippers | 2 | 3.0 cm3 | 0.071 |
| Strand guide grippers | 2 | 3.0 cm3 | 0.071 |
| **Total** | | | **3.37 L** |

At 6.5 s per cycle that is about 31 L/min of free air: a small load for a shop compressor (a 2 HP compressor gives roughly 200 L/min).

## 6. What this does not prove

- Strip force, crimp force and insertion force are typical figures, not measured. The bench rig measures them.
- Whether every strand goes into the ferrule, and whether the sleeve opens round. Only the bench test or the 3D-printed hand test answers that.
- Gripper forces are SMC catalogue values as I remember them; check the current catalogue before ordering.